ADD_OP_FEED_MARKER <op number>, <feature num>, <distance>, <value>, <type>, <marker num>


Add a feed marker to an operation.

Parameters

<op number>
Operation number.
<feature num>
Feature number.
<distance>
Distance along the feature (0.0 = start, 1.0 = end).
<value>
Feedrate value.
<type>
The feedrate type (1 = user, 2 = entry, 3 = contour, 4 = percent).
<type>
Name of variable to be set to the number of the marker that was added.

Example

ADD_OP_FEED_MARKER 1, 4, 0.5, 15, 1, MarkerNum